PROTECTING OUR AIR AND WATER WITH FLEXIBLE MEMBRANE
LINERS, COVERS, AND FABRICATIONS

 

Physical Properties - Hypalon-Based Geomembranes (back to specifications)


SHEET PROPERTIESStandardMetricStandardMetric
Gauge, nominal- -45 mil1.14mm36 mil .9mm
Piles, reinforcing- -1111
Thickness, minimum
Overall
Over scrim
ASTM D-751
Optical Method
41 mil
11 mil
1.04mm
.279mm
34 mil
11 mil
.86mm
.279mm
Breaking strength-fabric, minimumASTM D-751 Method A250 lbf1.1 kN200 lbf .89 kN
Tear strength, minimum
Initial
After aging
ASTM D-751
Tongue Tear
(Modified)
90 lbf
35 lbf
.40 kN
.16 kN
80 lbf
35 lbf
.36 kN
.16 kN
Puncture resistance,
minimum
FTMS 101C
Method 2031
200 lbs .89 kN 190 lbs .84 kN
Hydrostatic resistance,
minimum
ASTM D-751
Method A
Procedure 1
250 psi 1.7 MPa250 psi1.7 MPa
Dimensional stability,
maximum, % change
ASTM D-1204
1 hr. @ 180°F (82°C)
2% 2%2% 2%
Low temperature
flexibility
ASTM D-2136
1/8” Mandrel
4 hr. pass
-40°F -40°C -40°F -40°C
Ply adhesion,
minimum
ASTM D-413
Machine Method
Modified
8 lbs/in 1.4 kN/m10 lbs/in1.75 kN/m
UV resistanceASTM G26
Xenon Arc @ 80°C
Pass
4000 hrs.

TYPICAL FABRICATED SEAM PROPERTIES**

Bonded seam strength,
minimum
ASTM D-751*200 lbf.89 kN160 lbf.71 kN
Peel adhesion,
minimum
ASTM D-413*10 lbs/in1.75kN/m10 lbs/in1.75kN/m


*As modified in Annex, NSF-54                    **As made by others

All statements herein are expressions of opinion, which by performance and testing are believed to be accurate and reliable, but are presented without guarantee or responsibility on our part. Statements concerning possible use of our products are made without any knowledge that such recommended uses may infringe any patent. No warranty, expressed or implied, other than that described in this brochure, is made or intended.

 Sitemap | Privacy Policy

800-621-0146
4834 S. Oakley, Chicago, Illinois 60609-4036 phone 773-927-4120 fax 773-650-6028
info@mpccontainment.com